Welcome: ColorSpace 400-886-3881 400-886-3381
Language: Chinese ∷  English

Medical Charts

  • Angular Resolution & Depth of Field Test Chart
  • Angular Resolution & Depth of Field Test Chart
Angular Resolution & Depth of Field Test ChartAngular Resolution & Depth of Field Test Chart

Angular Resolution & Depth of Field Test Chart

  • Brand:ColorSpace
  • Model:CS-ECTS-TC05
  • Product description: ColorSpace has developed a series of endoscope test chart for medical and industrial endoscopic imaging systems. The CS-ECTS-TC05 angle resolution test chart (A1/A2) complies with the JB/T9328-1999 st
  • INQUIRY

CS-ECTS-TC05 Angular Resolution and Depth of Field Test Chart

ColorSpace develops the CS-ECTS-TC Series Endoscope Test Charts for evaluating the imaging performance of medical and industrial endoscopes. The CS-ECTS-TC05 Angular Resolution and Depth of Field Test Chart is designed for angular resolution testing and depth-of-field evaluation of endoscopic imaging systems.

The test chart uses A-type resolving power patterns based on JB/T 9328-1999 and can be used for angular resolution testing in accordance with YY 0068.1. By performing angular resolution measurements at different optical working distances, the chart can also be used to evaluate the effective depth of field of an endoscope.

The test chart is available in A1 and A2 patterns and features a transmissive film-on-glass construction. With a standard size of 160 mm × 134 mm, it can be directly mounted on the CS-ECTS Endoscope Test System for optical performance testing of medical and industrial endoscopes.


Key Features

01|Angular Resolution Testing

The test chart uses resolving power patterns with high-contrast line pairs to evaluate the ability of an endoscope to resolve fine image details at a specified optical working distance.According to YY 0068.1, angular resolution testing is performed using a resolving power test target with A-type resolving power patterns specified in JB/T 9328-1999, under defined test conditions.

02|Depth of Field Evaluation

For endoscopes with depth-of-field characteristics, angular resolution can be measured at different optical working distances to evaluate the effective depth of field.

By changing the distance between the endoscope and the test chart and repeating the angular resolution measurement, the range over which the endoscope maintains the required resolving performance can be evaluated.

03|A1 / A2 Resolving Power Patterns

The test chart is available with A1 and A2 patterns, allowing users to select the appropriate resolving power pattern according to the endoscope and test requirements.

04|Based on JB/T 9328-1999 Resolving Power Test Target

The test chart uses A-type resolving power patterns based on JB/T 9328-1999, Resolving Power Test Target, for evaluating the resolving capability of optical imaging systems.The A-type resolving power patterns are also referenced by YY 0068.1 for angular resolution testing of rigid endoscopes.

05|Compatible with the CS-ECTS Endoscope Test System

With a standard size of 160 mm × 134 mm, the CS-ECTS-TC05 can be directly mounted on the CS-ECTS Endoscope Test System for endoscope angular resolution and optical performance testing.


CS-ECTS-TC05角分辨力测试卡_正印科技


Technical Specifications

Item Angular Resolution and Depth of Field Test Chart
Model CS-ECTS-TC05
Standard Size 160mm × 134mm
Chart Type Transmissive
Pattern Options A1/A2
Related Standards

· JB/T 9328-1999 Standard Resolution Test Plate

· YY0068.1-2008-Medical endoscopes-rigid endoscopes-part 1: Optical Properties and test methods

Compatible System CS-ECTS Endoscope Test System


【Reserve a Lab】For more information about related products and testing services, please contactsales@colorspace.com.cn

正印科技公众号

Follow ColorSpace for  industry news/events/solutions

CONTACT US

Contact: sales@colorspace.com.cn

Phone: 15817270587

Tel: 400-886-3881(周一至周五 9:00~18:00)

Email: sales@colorspace.com.cn

Add: South Building #2-1101, Lv Di Qi Hang Office Building, Hou Sha Yu, Shun Yi District, Beijing, China

Scan the qr codeClose